Bioaerosols Reduction

AUTHORS
Jamie Balarashti, Study Director

FACILITY
Aerosol Research and Engineering Laboratories

Objective

To evaluate the efficacy of the NV900 on neutralizing bioaerosols. The device was assessed on four aerosolized biologicals: Staphylococcus epidermidis, MS2 bacteriophage, Aspergillus niger fungus, and Bacillus subtilis endospores.

Methodology

A large sealed aerosol test chamber was used to replicate a potentially contaminated room environment and to contain any potential release of aerosols into the surrounding environment. The chamber was equipped with an NV900, filtered HEPA inlets, digital internal temperature and humidity monitor, external humidifiers (for humidity control), lighting system, multiple sampling ports, aerosol mixing fans, and a HEPA filtered exhaust system that were operated with wireless remote control. For testing, the chamber was equipped with stainless steel probes for aerosol sampling, a port for bioaerosol dissemination into the chamber for the bacteriophages and vegetative cells, and a dry powder educator for the fungal and bacterial spores.

Summary of Results

Test results show that the NV900 was extremely effective at reducing the viability of bioaerosols in all conducted studies:

99.87% reduction of Staphylococcus epidermidis bacteria

99.99% reduction of MS2, a surrogate for influenza, norovirus, and SARS-CoV coronavirus

99.1% reduction of Aspergillus niger mold

86.63% reduction of Bacillus subtilis bacteria spore

Staph_Reduction_Graph